GHG Inventory · Sustainability Analytics

Carbon Footprint, Scope Emissions & Waste Dashboard

Bottom-up, activity-based inventory of a 900-bed tertiary hospital in Hyderabad, India, for financial year 2024 — built to the GHG Protocol corporate standard and the Health Care Without Harm Climate Impact Checkup methodology.

Hospital A (name withheld)Hyderabad, Telangana FY 2024 baseline900 beds 3,24,690 patient encounters56,868.7 m² built-up Grid EF 0.727 kgCO₂e/kWh (CEA v20.0)

Headline indicators

Total footprint
9,419.9
tCO₂e  ·  Scope 1+2+3
Scope 2 — grid electricity
74.4%
7,004.9 tCO₂e of the total
Energy-related share
88.7%
electricity + T&D losses
Carbon intensity
29.0
kgCO₂e per patient encounter
Waste-related
141.9
tCO₂e  ·  1.51% of total
Inventory completeness
6/15
categories quantified

Where the emissions sit

Emissions by scope donut chart
Top emission sources ranked bar chart

Scope inventory — full breakdown

Scope / categorytCO₂e% of totalStatus
Scope 2 — purchased energy7,004.9574.40%Quantified
  Purchased electricity7,004.9574.40%Quantified
  Purchased steam, heat & cooling0—Not occurring
Scope 3 — other indirect1,493.0215.80%Partial
  Electricity transmission & distribution losses1,354.0914.40%Quantified
  Off-site waste treatment138.941.50%Quantified
  Extra supply chain (procurement)0—Not estimated
  Business travel / employee / patient commuting0—Not estimated
  Inhalers (MDI / DPI)0—Not estimated
Scope 1 — direct921.959.80%Partial
  Fugitive — medicinal & anaesthetic gases867.449.20%Quantified
  Stationary combustion (boilers, DG sets)51.580.50%Quantified
  On-site waste treatment (composting)2.930.03%Quantified
  Mobile combustion (owned fleet)0—Not estimated
  Cooling & fire suppression (refrigerants)0—Not estimated
Total FY2024 footprint9,419.92100.00%

Note: the report prints Scope 1 as 921.99 tCO₂e in one table (p.36) and 921.95 tCO₂e elsewhere (pp.38, 42). The reconciled figure used here is 921.95, which sums exactly with Scope 2 and Scope 3 to the stated 9,419.92 t total.

Waste & biomedical waste

Waste streamtCO₂e% of wasteBoundaryBasis
Solid waste disposal (landfill)104.2773.5%Off-site, Scope 3CH₄ from anaerobic decay, 30-yr emissions booked upfront
Incineration — clinical / biohazardous / hazardous34.6724.4%Off-site, Scope 30.7 kgCO₂e/kg, fossil carbon fraction only
Composting2.932.1%On-site, Scope 1Reported separately from the Scope 3 waste line
Total waste-related emissions141.87100%1.51% of the facility footprint

Segregation is the leverage point, not tonnage: every kilogram shifted out of the incineration stream into recycling avoids 0.7 kgCO₂e, and avoided procurement of single-use items removes emissions upstream of the waste stream entirely.

Waste treatment emissions bar chart

Read the inventory before you trust it

Inventory completeness by scope
Scope 3 category coverage
The 74% Scope 2 figure is a data artefact as much as a finding. Procurement (extra supply chain), commuting, travel, inhalers, fleet and refrigerants were all marked not estimated. Globally, supply chain is ~71% of healthcare emissions; here it is 0%. That does not mean this hospital buys less — it means the largest Scope 3 block was never measured. Treat 9,419.9 t as a floor, not the full footprint.

Decarbonisation pathway

Decarbonisation pathway chart
LeverAddressesIndicative costIndicative return
Rooftop solar + renewable PPAScope 2 (74%), T&D losses₹35–40 lakh₹9–10 lakh/yr saved; 4–5 yr payback
Energy efficiency: LED, HVAC controls, efficient medical equipmentScope 2Not costed in reportCuts the same kWh base solar must cover
Low-GWP anaesthetic substitution + gas captureScope 1 (9.2%), 867 tCO₂eProtocol change~150% ROI over 3 years
Waste segregation, reduction, non-burn treatmentScope 3 waste (1.5%) + avoided procurementTraining & process₹2–3 lakh/yr saved
Green procurement criteria for suppliersUnquantified supply chainPolicy onlyAvoided carbon liability, not cash yet

Headline target in the report: 30–40% reduction over 3–5 years. The corridor above is illustrative, built from that stated range — it is a planning envelope, not a modelled forecast.

Method & boundaries

Design choiceWhat was applied
ApproachBottom-up, activity data × emission factor, per GHG Protocol and HCWH Climate Impact Checkup
Emission factorsGrid 0.727 kgCO₂e/kWh (CEA Baseline v20.0, Dec 2024); diesel 2.68 kg/L; LPG 2.983 kg/kg; desflurane GWP 2,540; isoflurane 510; waste incineration 0.7 kg/kg (CPCB 2023)
Anaesthetic activity data130 kg CO₂ (~66,327 L) and 46 kg N₂O (~24,892 L) consumed in the reporting period
Derived electricity7,004.95 t ÷ 0.727 kg/kWh ≈ 9,635 MWh annual consumption (implied, not metered in the report)
Intensity denominators3,24,690 patient encounters (29.0 kgCO₂e each); 900 beds (10.5 tCO₂e/bed); 56,868.7 m² (0.166 tCO₂e/m²)
Known limitationsSingle-year snapshot, no base-year trend, no uncertainty or assurance, six Scope 3 categories unquantified, refrigerant and fleet emissions absent